Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as main switchYes
Version as reversing switchNo
Version as safety switchNo
Rated permanent current at AC-23, 400 V13.3A
Rated operating voltage690 - 690V
Rated permanent current Iu20A
Number of switches1
Version as maintenance-/service switchYes
Max. rated operation voltage Ue AC690V
Version as emergency stop installationYes
Rated permanent current at AC-21, 400 V20A
Rated operation power at AC-3, 400 V5.5kW
Rated short-time withstand current lcw0.32kA
Conditioned rated short-circuit current Iq6kA
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Motor drive optionalNo
Switching power at 400 V5.5kW
Motor drive integratedNo
Device constructionComplete device in housing
Number of poles3
Rated operation power at AC-23, 400 V5.5kW
Voltage release optionalNo
Suitable for distribution board installationNo
Suitable for front mounting centreNo
Suitable for intermediate mountingNo
Suitable for floor mountingYes
Suitable for front mounting 4-holeNo
InterlockableYes
Colour control elementRed
Height110mm
With pre-assembled cablingNo
Type of control elementDoor coupling rotary drive
Degree of protection (IP), front sideIP65
Width80mm
Degree of protection (NEMA)12
Depth137mm
Type of electrical connection of main circuitScrew connection

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T0-2-8900/I1/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as main switch

Version as reversing switch

Version as safety switch

Rated permanent current at AC-23, 400 V

13.3A

Rated operating voltage

690 .. 690V

Rated permanent current Iu

20A

Number of switches

1

Version as maintenance-/service switch

Max. rated operation voltage Ue AC

690V

Version as emergency stop installation

Rated permanent current at AC-21, 400 V

20A

Rated operation power at AC-3, 400 V

5.5kW

Rated short-time withstand current lcw

0.32kA

Conditioned rated short-circuit current Iq

6kA

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Switching power at 400 V

5.5kW

Motor drive integrated

Device construction

Complete device in housing

Number of poles

3

Rated operation power at AC-23, 400 V

5.5kW

Voltage release optional

Suitable for distribution board installation

Suitable for front mounting centre

Suitable for intermediate mounting

Suitable for floor mounting

Suitable for front mounting 4-hole

Interlockable

Colour control element

Red

Height

110mm

With pre-assembled cabling

Type of control element

Door coupling rotary drive

Degree of protection (IP), front side

IP65

Width

80mm

Degree of protection (NEMA)

12

Depth

137mm

Type of electrical connection of main circuit

Screw connection

Related products