Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as reversing switchNo
Version as safety switchNo
Version as emergency stop installationNo
Version as main switchYes
Rated permanent current at AC-23, 400 V13.3A
Number of auxiliary contacts as normally open contact1
Switching power at 400 V5.5kW
Conditioned rated short-circuit current Iq6kA
Rated permanent current Iu20A
Number of poles4
Rated short-time withstand current lcw0.32kA
Rated operation power at AC-23, 400 V5.5kW
Motor drive optionalNo
Max. rated operation voltage Ue AC690V
Suitable for front mounting 4-holeNo
Suitable for floor mountingYes
Motor drive integratedNo
Rated operating voltage690 - 690V
Suitable for front mounting centreNo
InterlockableYes
Number of auxiliary contacts as normally closed contact1
Rated permanent current at AC-21, 400 V20A
Width80mm
Device constructionComplete device in housing
Degree of protection (IP), front sideIP65
Height130mm
Depth137mm
With pre-assembled cablingNo
Number of auxiliary contacts as change-over contact0
Suitable for distribution board installationNo
Version as maintenance-/service switchYes
Voltage release optionalNo
Type of electrical connection of main circuitScrew connection
Rated operation power at AC-3, 400 V5.5kW
Type of control elementDoor coupling rotary drive
Degree of protection (NEMA)12
Colour control elementBlack
Suitable for intermediate mountingNo
Number of switches1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T0-3-15680/I1/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as reversing switch

Version as safety switch

Version as emergency stop installation

Version as main switch

Rated permanent current at AC-23, 400 V

13.3A

Number of auxiliary contacts as normally open contact

1

Switching power at 400 V

5.5kW

Conditioned rated short-circuit current Iq

6kA

Rated permanent current Iu

20A

Number of poles

4

Rated short-time withstand current lcw

0.32kA

Rated operation power at AC-23, 400 V

5.5kW

Motor drive optional

Max. rated operation voltage Ue AC

690V

Suitable for front mounting 4-hole

Suitable for floor mounting

Motor drive integrated

Rated operating voltage

690 .. 690V

Suitable for front mounting centre

Interlockable

Number of auxiliary contacts as normally closed contact

1

Rated permanent current at AC-21, 400 V

20A

Width

80mm

Device construction

Complete device in housing

Degree of protection (IP), front side

IP65

Height

130mm

Depth

137mm

With pre-assembled cabling

Number of auxiliary contacts as change-over contact

0

Suitable for distribution board installation

Version as maintenance-/service switch

Voltage release optional

Type of electrical connection of main circuit

Screw connection

Rated operation power at AC-3, 400 V

5.5kW

Type of control element

Door coupling rotary drive

Degree of protection (NEMA)

12

Colour control element

Black

Suitable for intermediate mounting

Number of switches

1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.