Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC690V
Number of switches1
Version as maintenance-/service switchNo
Rated permanent current at AC-23, 400 V32A
Rated operation power at AC-3, 400 V11kW
Version as main switchNo
Rated permanent current Iu32A
Version as emergency stop installationNo
Version as safety switchNo
Version as reversing switchNo
Rated short-time withstand current lcw0.65kA
Rated operation power at AC-23, 400 V15kW
Rated permanent current at AC-21, 400 V32A
Switching power at 400 V15kW
Number of poles6
Conditioned rated short-circuit current Iq1kA
Number of auxiliary contacts as change-over contact0
Voltage release optionalNo
Device constructionComplete device in housing
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Motor drive optionalNo
Suitable for front mounting centreNo
Number of auxiliary contacts as normally closed contact0
Suitable for floor mountingYes
Suitable for distribution board installationNo
Colour control elementBlack
Suitable for intermediate mountingNo
Type of control elementShort thumb-grip
With pre-assembled cablingNo
Type of electrical connection of main circuitScrew connection
Suitable for front mounting 4-holeNo
InterlockableNo
Rated operating voltage690 - 690V
Degree of protection (IP), front sideIP65
Degree of protection (NEMA)12
Width100mm
Height127mm
Depth181mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T3-3-8342/I2

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Number of switches

1

Version as maintenance-/service switch

Rated permanent current at AC-23, 400 V

32A

Rated operation power at AC-3, 400 V

11kW

Version as main switch

Rated permanent current Iu

32A

Version as emergency stop installation

Version as safety switch

Version as reversing switch

Rated short-time withstand current lcw

0.65kA

Rated operation power at AC-23, 400 V

15kW

Rated permanent current at AC-21, 400 V

32A

Switching power at 400 V

15kW

Number of poles

6

Conditioned rated short-circuit current Iq

1kA

Number of auxiliary contacts as change-over contact

0

Voltage release optional

Device construction

Complete device in housing

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Suitable for front mounting centre

Number of auxiliary contacts as normally closed contact

0

Suitable for floor mounting

Suitable for distribution board installation

Colour control element

Black

Suitable for intermediate mounting

Type of control element

Short thumb-grip

With pre-assembled cabling

Type of electrical connection of main circuit

Screw connection

Suitable for front mounting 4-hole

Interlockable

Rated operating voltage

690 .. 690V

Degree of protection (IP), front side

IP65

Degree of protection (NEMA)

12

Width

100mm

Height

127mm

Depth

181mm

Related products