Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles1
Type of control elementDoor coupling rotary drive
Rated permanent current Iu63A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Device constructionComplete device in housing
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
Rated operation power at AC-3, 400 V22kW
Suitable for floor mountingYes
Suitable for intermediate mountingNo
Suitable for distribution board installationNo
Degree of protection (IP), front sideIP65
Degree of protection (NEMA)12
Conditioned rated short-circuit current Iq2kA
Rated operating voltage690 - 690V
Rated short-time withstand current lcw1.3kA
Max. rated operation voltage Ue AC690V
Suitable for front mounting 4-holeNo
Version as emergency stop installationNo
Version as reversing switchNo
Rated permanent current at AC-21, 400 V63A
InterlockableYes
Version as maintenance-/service switchYes
Switching power at 400 V30kW
Rated permanent current at AC-23, 400 V63A
Rated operation power at AC-23, 400 V30kW
Voltage release optionalNo
Suitable for front mounting centreNo
Version as safety switchNo
Number of switches1
Version as main switchYes
Colour control elementBlack
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5B-1-8200/I4/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles

1

Type of control element

Door coupling rotary drive

Rated permanent current Iu

63A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Device construction

Complete device in housing

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Rated operation power at AC-3, 400 V

22kW

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Degree of protection (IP), front side

IP65

Degree of protection (NEMA)

12

Conditioned rated short-circuit current Iq

2kA

Rated operating voltage

690 .. 690V

Rated short-time withstand current lcw

1.3kA

Max. rated operation voltage Ue AC

690V

Suitable for front mounting 4-hole

Version as emergency stop installation

Version as reversing switch

Rated permanent current at AC-21, 400 V

63A

Interlockable

Version as maintenance-/service switch

Switching power at 400 V

30kW

Rated permanent current at AC-23, 400 V

63A

Rated operation power at AC-23, 400 V

30kW

Voltage release optional

Suitable for front mounting centre

Version as safety switch

Number of switches

1

Version as main switch

Colour control element

Black

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.