Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as main switchNo
Rated permanent current Iu100A
Version as reversing switchNo
Number of switches1
Version as emergency stop installationNo
Rated operation power at AC-23, 400 V55kW
Max. rated operation voltage Ue AC690V
Rated operating voltage690 - 690V
Conditioned rated short-circuit current Iq80kA
Rated permanent current at AC-21, 400 V100A
Rated permanent current at AC-23, 400 V100A
Number of auxiliary contacts as normally closed contact0
Number of poles3
Motor drive optionalNo
Motor drive integratedNo
Switching power at 400 V55kW
Rated operation power at AC-3, 400 V37kW
Rated short-time withstand current lcw2kA
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Version as safety switchNo
Version as maintenance-/service switchNo
Voltage release optionalNo
Suitable for floor mountingYes
Suitable for front mounting 4-holeNo
Device constructionComplete device in housing
Suitable for distribution board installationNo
InterlockableNo
Degree of protection (IP), front sideIP65
Colour control elementBlack
With pre-assembled cablingNo
Suitable for front mounting centreNo
Suitable for intermediate mountingNo
Type of electrical connection of main circuitScrew connection
Degree of protection (NEMA)12
Type of control elementShort thumb-grip
Width200mm
Height280mm
Depth162mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

P3-100/I5

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as main switch

Rated permanent current Iu

100A

Version as reversing switch

Number of switches

1

Version as emergency stop installation

Rated operation power at AC-23, 400 V

55kW

Max. rated operation voltage Ue AC

690V

Rated operating voltage

690 .. 690V

Conditioned rated short-circuit current Iq

80kA

Rated permanent current at AC-21, 400 V

100A

Rated permanent current at AC-23, 400 V

100A

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Motor drive optional

Motor drive integrated

Switching power at 400 V

55kW

Rated operation power at AC-3, 400 V

37kW

Rated short-time withstand current lcw

2kA

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Version as safety switch

Version as maintenance-/service switch

Voltage release optional

Suitable for floor mounting

Suitable for front mounting 4-hole

Device construction

Complete device in housing

Suitable for distribution board installation

Interlockable

Degree of protection (IP), front side

IP65

Colour control element

Black

With pre-assembled cabling

Suitable for front mounting centre

Suitable for intermediate mounting

Type of electrical connection of main circuit

Screw connection

Degree of protection (NEMA)

12

Type of control element

Short thumb-grip

Width

200mm

Height

280mm

Depth

162mm