Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
Yes
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Number of switches
1
Rated permanent current Iu
100A
Rated permanent current at AC-23, 400 V
100A
Rated operation power at AC-3, 400 V
30kW
Rated short-time withstand current lcw
1.7kA
Rated operation power at AC-23, 400 V
55kW
Number of auxiliary contacts as normally closed contact
1
Rated permanent current at AC-21, 400 V
100A
Switching power at 400 V
55kW
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Conditioned rated short-circuit current Iq
2kA
Voltage release optional
No
Suitable for distribution board installation
No
Suitable for front mounting centre
Yes
Suitable for front mounting 4-hole
No
Motor drive integrated
No
Suitable for intermediate mounting
No
Colour control element
Black
With pre-assembled cabling
No
Degree of protection (NEMA)
12
Interlockable
Yes
Degree of protection (IP), front side
IP65
Type of control element
Door coupling rotary drive
Width
88mm
Height
88mm
Depth
173mm
Version as safety switch
No
Rated operating voltage
690 - 690V
Version as emergency stop installation
No
Number of poles
6
Number of auxiliary contacts as normally open contact
1
Suitable for floor mounting
No
Type of electrical connection of main circuit
Screw connection
Related products
T5-4-15682/EA/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
Version as reversing switch
Version as maintenance-/service switch
Number of switches
1
Rated permanent current Iu
100A
Rated permanent current at AC-23, 400 V
100A
Rated operation power at AC-3, 400 V
30kW
Rated short-time withstand current lcw
1.7kA
Rated operation power at AC-23, 400 V
55kW
Number of auxiliary contacts as normally closed contact
1
Rated permanent current at AC-21, 400 V
100A
Switching power at 400 V
55kW
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Device construction
Built-in device fixed built-in technique
Conditioned rated short-circuit current Iq
2kA
Voltage release optional
Suitable for distribution board installation
Suitable for front mounting centre
Suitable for front mounting 4-hole
Motor drive integrated
Suitable for intermediate mounting
Colour control element
Black
With pre-assembled cabling
Degree of protection (NEMA)
12
Interlockable
Degree of protection (IP), front side
IP65
Type of control element
Door coupling rotary drive
Width
88mm
Height
88mm
Depth
173mm
Version as safety switch
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Number of poles
6
Number of auxiliary contacts as normally open contact
1
Suitable for floor mounting
Type of electrical connection of main circuit
Screw connection
Related products
We use cookies to enhance your experience.