  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC690V
Version as safety switchNo
Version as reversing switchNo
Number of switches1
Rated operating voltage690 - 690V
Version as emergency stop installationYes
Rated permanent current at AC-23, 400 V100A
Switching power at 400 V55kW
Rated operation power at AC-3, 400 V30kW
Rated short-time withstand current lcw1.7kA
Rated permanent current at AC-21, 400 V100A
Version as maintenance-/service switchYes
Rated operation power at AC-23, 400 V55kW
Number of auxiliary contacts as normally closed contact1
Number of poles6
Conditioned rated short-circuit current Iq2kA
Number of auxiliary contacts as normally open contact1
Motor drive optionalNo
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu100A
Version as main switchYes
Suitable for front mounting 4-holeNo
Device constructionBuilt-in device fixed built-in technique
Voltage release optionalNo
Suitable for front mounting centreNo
Suitable for intermediate mountingYes
Suitable for floor mountingYes
Suitable for distribution board installationNo
Type of control elementDoor coupling rotary drive
With pre-assembled cablingNo
InterlockableYes
Type of electrical connection of main circuitScrew connection
Colour control elementRed
Height88mm
Degree of protection (IP), front sideIP65
Width88mm
Depth188mm
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5-4-15682/V/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Version as safety switch

Version as reversing switch

Number of switches

1

Rated operating voltage

690 .. 690V

Version as emergency stop installation

Rated permanent current at AC-23, 400 V

100A

Switching power at 400 V

55kW

Rated operation power at AC-3, 400 V

30kW

Rated short-time withstand current lcw

1.7kA

Rated permanent current at AC-21, 400 V

100A

Version as maintenance-/service switch

Rated operation power at AC-23, 400 V

55kW

Number of auxiliary contacts as normally closed contact

1

Number of poles

6

Conditioned rated short-circuit current Iq

2kA

Number of auxiliary contacts as normally open contact

1

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

100A

Version as main switch

Suitable for front mounting 4-hole

Device construction

Built-in device fixed built-in technique

Voltage release optional

Suitable for front mounting centre

Suitable for intermediate mounting

Suitable for floor mounting

Suitable for distribution board installation

Type of control element

Door coupling rotary drive

With pre-assembled cabling

Interlockable

Type of electrical connection of main circuit

Screw connection

Colour control element

Red

Height

88mm

Degree of protection (IP), front side

IP65

Width

88mm

Depth

188mm

Degree of protection (NEMA)

12