Max. rated operation voltage Ue AC690V
Version as main switchYes
Version as maintenance-/service switchYes
Version as safety switchNo
Rated permanent current Iu100A
Rated permanent current at AC-23, 400 V100A
Rated operation power at AC-23, 400 V55kW
Rated permanent current at AC-21, 400 V100A
Rated operating voltage690 - 690V
Version as emergency stop installationNo
Switching power at 400 V55kW
Number of switches1
Conditioned rated short-circuit current Iq2kA
Number of poles6
Rated short-time withstand current lcw1.7kA
Number of auxiliary contacts as normally closed contact1
Motor drive integratedNo
Number of auxiliary contacts as normally open contact1
Device constructionBuilt-in device fixed built-in technique
Version as reversing switchNo
Suitable for floor mountingYes
Suitable for front mounting 4-holeNo
Number of auxiliary contacts as change-over contact0
Suitable for front mounting centreNo
Rated operation power at AC-3, 400 V30kW
Voltage release optionalNo
Motor drive optionalNo
Type of control elementDoor coupling rotary drive
Height88mm
InterlockableYes
Depth188mm
Suitable for distribution board installationNo
Colour control elementBlack
Suitable for intermediate mountingYes
With pre-assembled cablingNo
Degree of protection (IP), front sideIP65
Width88mm
Type of electrical connection of main circuitScrew connection
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5-4-15682/V/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Version as main switch

Version as maintenance-/service switch

Version as safety switch

Rated permanent current Iu

100A

Rated permanent current at AC-23, 400 V

100A

Rated operation power at AC-23, 400 V

55kW

Rated permanent current at AC-21, 400 V

100A

Rated operating voltage

690 .. 690V

Version as emergency stop installation

Switching power at 400 V

55kW

Number of switches

1

Conditioned rated short-circuit current Iq

2kA

Number of poles

6

Rated short-time withstand current lcw

1.7kA

Number of auxiliary contacts as normally closed contact

1

Motor drive integrated

Number of auxiliary contacts as normally open contact

1

Device construction

Built-in device fixed built-in technique

Version as reversing switch

Suitable for floor mounting

Suitable for front mounting 4-hole

Number of auxiliary contacts as change-over contact

0

Suitable for front mounting centre

Rated operation power at AC-3, 400 V

30kW

Voltage release optional

Motor drive optional

Type of control element

Door coupling rotary drive

Height

88mm

Interlockable

Depth

188mm

Suitable for distribution board installation

Colour control element

Black

Suitable for intermediate mounting

With pre-assembled cabling

Degree of protection (IP), front side

IP65

Width

88mm

Type of electrical connection of main circuit

Screw connection

Degree of protection (NEMA)

12