Technical specifications

Max. rated operation voltage Ue AC690V
Version as main switchNo
Number of switches1
Version as safety switchNo
Version as reversing switchNo
Rated permanent current Iu63A
Rated permanent current at AC-23, 400 V63A
Rated short-time withstand current lcw1.3kA
Version as emergency stop installationNo
Switching power at 400 V30kW
Rated operation power at AC-3, 400 V22kW
Version as maintenance-/service switchNo
Conditioned rated short-circuit current Iq2kA
Rated operation power at AC-23, 400 V30kW
Number of auxiliary contacts as change-over contact0
Rated permanent current at AC-21, 400 V63A
Rated operating voltage690 - 690V
Number of poles6
Voltage release optionalNo
Device constructionComplete device in housing
Suitable for floor mountingYes
Suitable for front mounting 4-holeNo
Suitable for intermediate mountingNo
Colour control elementBlack
Suitable for distribution board installationNo
Number of auxiliary contacts as normally closed contact1
Motor drive integratedNo
Type of control elementShort thumb-grip
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact1
Degree of protection (IP), front sideIP65
With pre-assembled cablingNo
Motor drive optionalNo
Height197mm
Depth240mm
Suitable for front mounting centreNo
Width160mm
Degree of protection (NEMA)12
InterlockableNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5B-4-15164/I4

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Version as main switch

Number of switches

1

Version as safety switch

Version as reversing switch

Rated permanent current Iu

63A

Rated permanent current at AC-23, 400 V

63A

Rated short-time withstand current lcw

1.3kA

Version as emergency stop installation

Switching power at 400 V

30kW

Rated operation power at AC-3, 400 V

22kW

Version as maintenance-/service switch

Conditioned rated short-circuit current Iq

2kA

Rated operation power at AC-23, 400 V

30kW

Number of auxiliary contacts as change-over contact

0

Rated permanent current at AC-21, 400 V

63A

Rated operating voltage

690 .. 690V

Number of poles

6

Voltage release optional

Device construction

Complete device in housing

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for intermediate mounting

Colour control element

Black

Suitable for distribution board installation

Number of auxiliary contacts as normally closed contact

1

Motor drive integrated

Type of control element

Short thumb-grip

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

1

Degree of protection (IP), front side

IP65

With pre-assembled cabling

Motor drive optional

Height

197mm

Depth

240mm

Suitable for front mounting centre

Width

160mm

Degree of protection (NEMA)

12

Interlockable