Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of poles0
Version as maintenance-/service switchYes
Max. rated operation voltage Ue AC690V
Version as emergency stop installationNo
Rated operating voltage690 - 690V
Version as safety switchNo
Rated permanent current at AC-23, 400 V100A
Rated permanent current at AC-21, 400 V100A
Rated short-time withstand current lcw1.7kA
Rated operation power at AC-23, 400 V55kW
Switching power at 400 V55kW
Rated operation power at AC-3, 400 V30kW
Motor drive optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Conditioned rated short-circuit current Iq2kA
Version as main switchYes
Suitable for floor mountingYes
Number of auxiliary contacts as change-over contact0
Number of switches1
Suitable for front mounting 4-holeNo
Voltage release optionalNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Suitable for distribution board installationNo
Suitable for front mounting centreNo
Rated permanent current Iu100A
Version as reversing switchNo
Depth221mm
Suitable for intermediate mountingYes
Height88mm
Type of electrical connection of main circuitScrew connection
Degree of protection (NEMA)12
Colour control elementRed
Degree of protection (IP), front sideIP65
With pre-assembled cablingNo
Width88mm
InterlockableYes
Type of control elementDoor coupling rotary drive

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5-6-SOND*/V/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of poles

0

Version as maintenance-/service switch

Max. rated operation voltage Ue AC

690V

Version as emergency stop installation

Rated operating voltage

690 .. 690V

Version as safety switch

Rated permanent current at AC-23, 400 V

100A

Rated permanent current at AC-21, 400 V

100A

Rated short-time withstand current lcw

1.7kA

Rated operation power at AC-23, 400 V

55kW

Switching power at 400 V

55kW

Rated operation power at AC-3, 400 V

30kW

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Conditioned rated short-circuit current Iq

2kA

Version as main switch

Suitable for floor mounting

Number of auxiliary contacts as change-over contact

0

Number of switches

1

Suitable for front mounting 4-hole

Voltage release optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Suitable for distribution board installation

Suitable for front mounting centre

Rated permanent current Iu

100A

Version as reversing switch

Depth

221mm

Suitable for intermediate mounting

Height

88mm

Type of electrical connection of main circuit

Screw connection

Degree of protection (NEMA)

12

Colour control element

Red

Degree of protection (IP), front side

IP65

With pre-assembled cabling

Width

88mm

Interlockable

Type of control element

Door coupling rotary drive

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.