Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Number of poles
0
Max. rated operation voltage Ue AC
690V
Version as main switch
Yes
Number of switches
1
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Version as safety switch
No
Version as emergency stop installation
No
Rated short-time withstand current lcw
1.3kA
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Rated permanent current at AC-23, 400 V
63A
Switching power at 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Voltage release optional
No
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-23, 400 V
30kW
Motor drive optional
No
Suitable for floor mounting
Yes
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
No
Motor drive integrated
No
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Rated operation power at AC-3, 400 V
22kW
Height
88mm
Degree of protection (NEMA)
12
Interlockable
Yes
Suitable for distribution board installation
No
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
Yes
Width
88mm
Number of auxiliary contacts as normally closed contact
0
Colour control element
Black
Device construction
Built-in device fixed built-in technique
Degree of protection (IP), front side
IP65
Type of control element
Door coupling rotary drive
Rated operating voltage
690 - 690V
Depth
188mm
Related products
T5B-4-SOND*/V/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Number of poles
0
Max. rated operation voltage Ue AC
690V
Version as main switch
Number of switches
1
Version as maintenance-/service switch
Version as reversing switch
Version as safety switch
Version as emergency stop installation
Rated short-time withstand current lcw
1.3kA
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Rated permanent current at AC-23, 400 V
63A
Switching power at 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Voltage release optional
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-23, 400 V
30kW
Motor drive optional
Suitable for floor mounting
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
Motor drive integrated
Suitable for front mounting centre
Suitable for front mounting 4-hole
Rated operation power at AC-3, 400 V
22kW
Height
88mm
Degree of protection (NEMA)
12
Interlockable
Suitable for distribution board installation
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
Width
88mm
Number of auxiliary contacts as normally closed contact
0
Colour control element
Black
Device construction
Built-in device fixed built-in technique
Degree of protection (IP), front side
IP65
Type of control element
Door coupling rotary drive
Rated operating voltage
690 .. 690V
Depth
188mm