Technical specifications

Rated permanent current Iu6.3A
Power loss4.94W
Number of poles3
With integrated under voltage releaseNo
Integrated earth fault protectionNo
Position of connection for main current circuitOther
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting4 - 6.3A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release141 - 141A
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingYes
Type of control elementTurn button
Complete device with protection unitYes
Motor drive optionalNo
Motor drive integratedNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKZM0-6,3-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

6.3A

Power loss

4.94W

Number of poles

3

With integrated under voltage release

Integrated earth fault protection

Position of connection for main current circuit

Other

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

4 .. 6.3A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

141 .. 141A

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Type of control element

Turn button

Complete device with protection unit

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20