Technical specifications
MSC-D-16-M15(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Height
180mm
Width
45mm
Depth
95mm
Rated operation power at AC-3, 400 V
7.5kW
Number of command positions
0
With transformer
Supporting protocol for ASI
Suitable for emergency stop
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Power consumption
2.6W
Supporting protocol for LON
Overload release current setting
10 .. 16A
Supporting protocol for TCP/IP
Rated operation current Ie
15.2A
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Number of indicator lights
0
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
External reset possible
Supporting protocol for other bus systems
Rail mounting possible
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Release class
CLASS 10 A
With short-circuit release
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Supporting protocol for EtherNet/IP
Temperature compensated overload protection
Supporting protocol for PROFINET CBA
Rated operation power at AC-3, 230 V, 3-phase
4kW
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Rated operation current at AC-3, 400 V
15A
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Ambient temperature, upper operating limit
55°C
Voltage type for actuating
DC
Supporting protocol for AS-Interface Safety at Work
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for Foundation Fieldbus
Type of motor starter
Direct online starter (DOL)
With fuse
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 2, 400 V
50A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Coordination class according to IEC 60947-4-3
Class 1