Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ230 - 230V
With short-circuit releaseYes
Type of motor starterDirect online starter (DOL)
Rated control supply voltage Us at DC0 - 0V
Rated operation power at AC-3, 400 V5.5kW
Rated operation power at AC-3, 230 V, 3-phase3kW
Overload release current setting8 - 12A
Rated operation current Ie11.3A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V12A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Number of auxiliary contacts as normally open contact1
Power consumption2.1W
Voltage type for actuatingAC
Ambient temperature, upper operating limit55°C
Number of auxiliary contacts as normally closed contact0
Release classCLASS 10 A
Rail mounting possibleNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With transformerNo
Suitable for emergency stopNo
Temperature compensated overload protectionYes
Number of indicator lights0
Number of command positions0
With fuseNo
Degree of protection (NEMA)Other
External reset possibleNo
Degree of protection (IP)IP00
Supporting protocol for TCP/IPNo
Coordination class according to IEC 60947-4-3Class 2
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width45mm
Height228mm
Depth123.4mm
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-12-M17(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 400 V

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Overload release current setting

8 .. 12A

Rated operation current Ie

11.3A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

12A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Voltage type for actuating

AC

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10 A

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Suitable for emergency stop

Temperature compensated overload protection

Number of indicator lights

0

Number of command positions

0

With fuse

Degree of protection (NEMA)

Other

External reset possible

Degree of protection (IP)

IP00

Supporting protocol for TCP/IP

Coordination class according to IEC 60947-4-3

Class 2

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

228mm

Depth

123.4mm

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.