Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •Motor-starter combination direct, 24V DC cont
  • •Low-voltage industrial components
  • •Motor starter/motor starter combination
  • •Minimum order quantity: 1 pcs
  • •EATON

Technical specifications

Width45mm
Depth123.4mm
Height228mm
Power consumption0.9W
With transformerNo
Number of command positions0
Number of indicator lights0
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact0
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
External reset possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
Release classCLASS 10 A
With short-circuit releaseYes
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Supporting protocol for PROFINET CBANo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingDC
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation power at AC-3, 400 V4kW
Rated operation current Ie8.5A
Overload release current setting6.3 - 10A
Degree of protection (IP)IP00
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V10A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as