Rated permanent current Iu12A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Power loss6.37W
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingYes
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release224 - 224A
Overload release current setting8 - 12A
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitOther
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Motor drive optionalNo
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Type of control elementTurn button
Number of poles3
Complete device with protection unitYes
With integrated under voltage releaseNo
With switched-off indicatorYes
Device constructionBuilt-in device fixed built-in technique

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKZM0-12-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

12A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Power loss

6.37W

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

224 .. 224A

Overload release current setting

8 .. 12A

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Other

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Type of control element

Turn button

Number of poles

3

Complete device with protection unit

With integrated under voltage release

With switched-off indicator

Device construction

Built-in device fixed built-in technique