Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Height180mm
Depth95mm
Width45mm
Number of command positions0
Number of auxiliary contacts as normally closed contact0
Power consumption1.4W
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V0.06kW
Supporting protocol for TCP/IPNo
Overload release current setting0.16 - 0.25A
Supporting protocol for LONNo
Rated operation current Ie0.21A
Number of indicator lights0
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for CANNo
Supporting protocol for ModbusNo
External reset possibleNo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rail mounting possibleNo
Supporting protocol for INTERBUSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Release classCLASS 10 A
With short-circuit releaseYes
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Degree of protection (IP)IP20
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
With fuseNo
Voltage type for actuatingAC
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V0.25A
Rated operation power at AC-3, 230 V, 3-phase0.04kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V50000A
Type of motor starterDirect online starter (DOL)
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 2, 230 V50000A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-0,25-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Height

180mm

Depth

95mm

Width

45mm

Number of command positions

0

Number of auxiliary contacts as normally closed contact

0

Power consumption

1.4W

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Rated operation power at AC-3, 400 V

0.06kW

Supporting protocol for TCP/IP

Overload release current setting

0.16 .. 0.25A

Supporting protocol for LON

Rated operation current Ie

0.21A

Number of indicator lights

0

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for CAN

Supporting protocol for Modbus

External reset possible

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rail mounting possible

Supporting protocol for INTERBUS

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10 A

With short-circuit release

Type of electrical connection of main circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Degree of protection (IP)

IP20

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

With fuse

Voltage type for actuating

AC

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

0.25A

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Type of motor starter

Direct online starter (DOL)

Ambient temperature, upper operating limit

55°C

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 2, 230 V

50000A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.