Aleta.hr
Main Product Image

MSC-D-0,25-M7(230V50HZ)

Code: 1046636

ManufacturerRAZNO
Catalog number281925
Type
EAN code4015082819255

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Yes

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated control supply voltage Us at AC 50HZ

230 - 230V

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

0.06kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated operation current Ie

0.21A

Overload release current setting

0.16 - 0.25A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Rated operation current at AC-3, 400 V

0.25A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Yes

Number of auxiliary contacts as normally open contact

1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

No

Coordination class according to IEC 60947-4-3

Class 2

With transformer

No

Suitable for emergency stop

No

Number of command positions

0

Supporting protocol for DeviceNet Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Depth

95mm

Width

45mm

Height

180mm

Supporting protocol for INTERBUS-Safety

No

Number of indicator lights

0

With fuse

No

Degree of protection (NEMA)

Other

External reset possible

No

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for ASI

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for Modbus

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for LON

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-0,25-M7(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

0.06kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated operation current Ie

0.21A

Overload release current setting

0.16 .. 0.25A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Rated operation current at AC-3, 400 V

0.25A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Number of auxiliary contacts as normally open contact

1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

Coordination class according to IEC 60947-4-3

Class 2

With transformer

Suitable for emergency stop

Number of command positions

0

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Depth

95mm

Width

45mm

Height

180mm

Supporting protocol for INTERBUS-Safety

Number of indicator lights

0

With fuse

Degree of protection (NEMA)

Other

External reset possible

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.