Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact1
Overload release current setting0.4 - 0.63A
Width45mm
Rated operation power at AC-3, 400 V0.18kW
Supporting protocol for TCP/IPNo
Depth95mm
Number of indicator lights0
With transformerNo
Height180mm
Number of command positions0
Power consumption1.4W
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Rated operation current Ie0.6A
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Supporting protocol for other bus systemsNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for ModbusNo
External reset possibleNo
With short-circuit releaseYes
Supporting protocol for SERCOSNo
Release classCLASS 10 A
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Rail mounting possibleNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at AC 60HZ0 - 0V
With fuseNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNet SafetyNo
Degree of protection (IP)IP20
Supporting protocol for Data-HighwayNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUSNo
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at DC0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V50000A
Supporting protocol for Foundation FieldbusNo
Coordination class according to IEC 60947-4-3Class 2
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET IONo
Temperature compensated overload protectionYes
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V0.63A
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation power at AC-3, 230 V, 3-phase0.09kW
Ambient temperature, upper operating limit55°C
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-0,63-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

1

Overload release current setting

0.4 .. 0.63A

Width

45mm

Rated operation power at AC-3, 400 V

0.18kW

Supporting protocol for TCP/IP

Depth

95mm

Number of indicator lights

0

With transformer

Height

180mm

Number of command positions

0

Power consumption

1.4W

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Rated operation current Ie

0.6A

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Modbus

External reset possible

With short-circuit release

Supporting protocol for SERCOS

Release class

CLASS 10 A

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With fuse

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Degree of protection (IP)

IP20

Supporting protocol for Data-Highway

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

0 .. 0V

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Supporting protocol for Foundation Fieldbus

Coordination class according to IEC 60947-4-3

Class 2

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET IO

Temperature compensated overload protection

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

0.63A

Supporting protocol for SafetyBUS p

Voltage type for actuating

AC

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Ambient temperature, upper operating limit

55°C

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.