Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-D-1-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
With transformer
Height
180mm
Depth
95mm
Number of command positions
0
Rated operation power at AC-3, 400 V
0.25kW
Power consumption
1.4W
Suitable for emergency stop
Rail mounting possible
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally open contact
1
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
External reset possible
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for other bus systems
Supporting protocol for CAN
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Number of indicator lights
0
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Overload release current setting
0.63 .. 1A
Rated operation current Ie
0.8A
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of electrical connection of main circuit
Screw connection
With fuse
Temperature compensated overload protection
With short-circuit release
Rated power, 460 V, 60 Hz, 3-phase
0kW
Release class
CLASS 10 A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Ambient temperature, upper operating limit
55°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Voltage type for actuating
AC
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for SafetyBUS p
Rated operation current at AC-3, 400 V
1A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 2