Aleta.hr
Main Product Image

MSC-D-1-M7(230V50HZ)

Code: 1046639

ManufacturerRAZNO
Catalog number281929
Type
EAN code4015082819293

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated operation current Ie

0.8A

Rated operation power at AC-3, 400 V

0.25kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

0.63 - 1A

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated conditional short-circuit current, type 2, 400 V

50000A

Power consumption

1.4W

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rail mounting possible

No

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of electrical connection of main circuit

Screw connection

Rated conditional short-circuit current, type 2, 230 V

50000A

With transformer

No

Rated operation current at AC-3, 400 V

1A

Rated power, 460 V, 60 Hz, 3-phase

0kW

With short-circuit release

Yes

Release class

CLASS 10 A

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

Number of command positions

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

No

Number of indicator lights

0

Degree of protection (NEMA)

Other

External reset possible

No

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

No

Supporting protocol for CAN

No

Temperature compensated overload protection

Yes

Supporting protocol for ASI

No

With fuse

No

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Height

180mm

Width

45mm

Depth

95mm

Supporting protocol for DeviceNet

No

Supporting protocol for Data-Highway

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for Modbus

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFINET CBA

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-1-M7(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated operation current Ie

0.8A

Rated operation power at AC-3, 400 V

0.25kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

0.63 .. 1A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated conditional short-circuit current, type 2, 400 V

50000A

Power consumption

1.4W

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rail mounting possible

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of electrical connection of main circuit

Screw connection

Rated conditional short-circuit current, type 2, 230 V

50000A

With transformer

Rated operation current at AC-3, 400 V

1A

Rated power, 460 V, 60 Hz, 3-phase

0kW

With short-circuit release

Release class

CLASS 10 A

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

Number of command positions

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

Number of indicator lights

0

Degree of protection (NEMA)

Other

External reset possible

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for CAN

Temperature compensated overload protection

Supporting protocol for ASI

With fuse

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Height

180mm

Width

45mm

Depth

95mm

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.