- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Rated operation current Ie
0.8A
Rated operation power at AC-3, 400 V
0.25kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Overload release current setting
0.63 - 1A
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated conditional short-circuit current, type 2, 400 V
50000A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Rail mounting possible
No
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
No
Rated operation current at AC-3, 400 V
1A
Rated power, 460 V, 60 Hz, 3-phase
0kW
With short-circuit release
Yes
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Number of command positions
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
No
Number of indicator lights
0
Degree of protection (NEMA)
Other
External reset possible
No
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Temperature compensated overload protection
Yes
Supporting protocol for ASI
No
With fuse
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Height
180mm
Width
45mm
Depth
95mm
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for Modbus
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
From same serie
MSC-D-1-M7(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Rated operation current Ie
0.8A
Rated operation power at AC-3, 400 V
0.25kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Overload release current setting
0.63 .. 1A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated conditional short-circuit current, type 2, 400 V
50000A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Rail mounting possible
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
Rated operation current at AC-3, 400 V
1A
Rated power, 460 V, 60 Hz, 3-phase
0kW
With short-circuit release
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Number of command positions
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
Number of indicator lights
0
Degree of protection (NEMA)
Other
External reset possible
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS
Supporting protocol for CAN
Temperature compensated overload protection
Supporting protocol for ASI
With fuse
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Height
180mm
Width
45mm
Depth
95mm
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Modbus
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA