Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-D-1,6-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Height
180mm
With transformer
Depth
95mm
Rated operation power at AC-3, 400 V
0.55kW
Power consumption
1.4W
Width
45mm
Number of command positions
0
Suitable for emergency stop
Overload release current setting
1 .. 1.6A
Number of indicator lights
0
Rated operation current Ie
1.5A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Supporting protocol for LON
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Rail mounting possible
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for SERCOS
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for INTERBUS-Safety
External reset possible
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With short-circuit release
With fuse
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Type of motor starter
Direct online starter (DOL)
Supporting protocol for SafetyBUS p
Degree of protection (NEMA)
Other
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for PROFINET CBA
Temperature compensated overload protection
Rated operation power at AC-3, 230 V, 3-phase
0.25kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for PROFIsafe
Rated operation current at AC-3, 400 V
1.6A
Coordination class according to IEC 60947-4-3
Class 2
Voltage type for actuating
AC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 2, 400 V
50000A