Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
With transformerNo
Depth95mm
Width45mm
Height180mm
Number of auxiliary contacts as normally open contact1
Power consumption1.4W
Supporting protocol for LONNo
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Number of indicator lights0
Number of command positions0
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
External reset possibleNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Type of electrical connection of main circuitScrew connection
Release classCLASS 10 A
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Rail mounting possibleNo
With fuseNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingAC
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
Degree of protection (NEMA)Other
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Rated conditional short-circuit current, type 2, 400 V50000A
Coordination class according to IEC 60947-4-3Class 2
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation power at AC-3, 400 V0.75kW
Rated operation current Ie1.9A
Overload release current setting1.6 - 2.5A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC0 - 0V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V2.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user