Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 - 0V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
2.5 - 4A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation current Ie
3.6A
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated operation current at AC-3, 400 V
4A
Number of auxiliary contacts as normally closed contact
0
Rail mounting possible
No
Temperature compensated overload protection
Yes
Release class
CLASS 10
Rated power, 575 V, 60 Hz, 3-phase
0kW
Power consumption
1.4W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
With transformer
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Rated operation power at AC-3, 400 V
1.5kW
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
180mm
Depth
95mm
Supporting protocol for INTERBUS-Safety
No
Number of indicator lights
0
Number of command positions
0
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for PROFIBUS
No
Suitable for emergency stop
No
With fuse
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFINET IO
No
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET CBA
No
External reset possible
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
From same serie
MSC-D-4-M7(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
2.5 .. 4A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation current Ie
3.6A
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated operation current at AC-3, 400 V
4A
Number of auxiliary contacts as normally closed contact
0
Rail mounting possible
Temperature compensated overload protection
Release class
CLASS 10
Rated power, 575 V, 60 Hz, 3-phase
0kW
Power consumption
1.4W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
With transformer
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Rated operation power at AC-3, 400 V
1.5kW
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
180mm
Depth
95mm
Supporting protocol for INTERBUS-Safety
Number of indicator lights
0
Number of command positions
0
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for PROFIBUS
Suitable for emergency stop
With fuse
Supporting protocol for EtherNet/IP
Supporting protocol for CAN
Supporting protocol for PROFINET IO
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
Supporting protocol for PROFINET CBA
External reset possible
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SERCOS