Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth95mm
Height180mm
Width45mm
Number of command positions0
Number of auxiliary contacts as normally open contact1
With transformerNo
Power consumption1.4W
Rated operation current Ie5A
Number of auxiliary contacts as normally closed contact0
Rated operation power at AC-3, 400 V2.2kW
Suitable for emergency stopNo
Overload release current setting4 - 6.3A
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at DC0 - 0V
Type of electrical connection of main circuitScrew connection
With fuseNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rail mounting possibleNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
With short-circuit releaseYes
External reset possibleNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Release classCLASS 10
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Type of motor starterDirect online starter (DOL)
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingAC
Rated control supply voltage Us at AC 60HZ0 - 0V
Degree of protection (IP)IP20
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated operation current at AC-3, 400 V6.3A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V50000A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-6,3-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

95mm

Height

180mm

Width

45mm

Number of command positions

0

Number of auxiliary contacts as normally open contact

1

With transformer

Power consumption

1.4W

Rated operation current Ie

5A

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 400 V

2.2kW

Suitable for emergency stop

Overload release current setting

4 .. 6.3A

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for LON

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Rated control supply voltage Us at DC

0 .. 0V

Type of electrical connection of main circuit

Screw connection

With fuse

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rail mounting possible

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

With short-circuit release

External reset possible

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for PROFIsafe

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Type of motor starter

Direct online starter (DOL)

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Degree of protection (IP)

IP20

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

6.3A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 400 V

50000A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2