Aleta.hr
Main Product Image

MSC-D-12-M12(230V50HZ)

Code: 1046650

ManufacturerRAZNO
Catalog number283148
Type
EAN code4015082831486

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Yes

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated conditional short-circuit current, type 2, 400 V

50A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Yes

Number of auxiliary contacts as normally closed contact

0

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

8 - 12A

Release class

CLASS 10 A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

0A

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

12A

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated control supply voltage Us at DC

0 - 0V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

No

Number of command positions

0

Power consumption

1.4W

Suitable for emergency stop

No

With fuse

No

Degree of protection (NEMA)

Other

Supporting protocol for CAN

No

With transformer

No

Supporting protocol for PROFIBUS

No

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for DeviceNet

No

Supporting protocol for Modbus

No

Supporting protocol for LON

No

External reset possible

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

No

Supporting protocol for Data-Highway

No

Number of indicator lights

0

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

180mm

Depth

95mm


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-12-M12(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated conditional short-circuit current, type 2, 400 V

50A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Number of auxiliary contacts as normally closed contact

0

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

8 .. 12A

Release class

CLASS 10 A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

0A

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

12A

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated control supply voltage Us at DC

0 .. 0V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

Number of command positions

0

Power consumption

1.4W

Suitable for emergency stop

With fuse

Degree of protection (NEMA)

Other

Supporting protocol for CAN

With transformer

Supporting protocol for PROFIBUS

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for LON

External reset possible

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Number of indicator lights

0

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

180mm

Depth

95mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.