Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 - 0V
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Yes
Rated control supply voltage Us at DC
0 - 0V
Rated operation power at AC-3, 230 V, 3-phase
4kW
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
16A
Rated operation current Ie
15.2A
Rated operation power at AC-3, 400 V
7.5kW
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
10 - 16A
Ambient temperature, upper operating limit
55°C
Power consumption
2.1W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Yes
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Release class
CLASS 10 A
Rail mounting possible
No
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
Number of command positions
0
External reset possible
No
Supporting protocol for TCP/IP
No
With fuse
No
Suitable for emergency stop
No
Degree of protection (IP)
IP00
Supporting protocol for CAN
No
Degree of protection (NEMA)
Other
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Width
45mm
Height
228mm
Depth
123.4mm
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
From same serie
MSC-D-16-M17(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated control supply voltage Us at DC
0 .. 0V
Rated operation power at AC-3, 230 V, 3-phase
4kW
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
16A
Rated operation current Ie
15.2A
Rated operation power at AC-3, 400 V
7.5kW
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
10 .. 16A
Ambient temperature, upper operating limit
55°C
Power consumption
2.1W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Release class
CLASS 10 A
Rail mounting possible
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
Number of command positions
0
External reset possible
Supporting protocol for TCP/IP
With fuse
Suitable for emergency stop
Degree of protection (IP)
IP00
Supporting protocol for CAN
Degree of protection (NEMA)
Other
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Width
45mm
Height
228mm
Depth
123.4mm
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
From same serie
We use cookies to enhance your experience.