Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated operation power at AC-3, 400 V7.5kW
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Depth123.4mm
Number of command positions0
Overload release current setting10 - 16A
Number of auxiliary contacts as normally open contact1
Number of indicator lights0
Supporting protocol for CANNo
Rated operation current Ie15.2A
With transformerNo
Suitable for emergency stopNo
Supporting protocol for DeviceNetNo
Width45mm
Height228mm
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Power consumption2.1W
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for other bus systemsNo
With fuseNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SERCOSNo
Degree of protection (IP)IP00
Rail mounting possibleNo
External reset possibleNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at DC0 - 0V
Release classCLASS 10 A
Rated control supply voltage Us at AC 50HZ230 - 230V
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Rated operation power at AC-3, 230 V, 3-phase4kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Voltage type for actuatingAC
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Type of motor starterDirect online starter (DOL)
Rated conditional short-circuit current, type 2, 400 V50000A
Coordination class according to IEC 60947-4-3Class 2
Rated operation current at AC-3, 400 V16A
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 460 V, 60 Hz, 3-phase0kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M17(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated operation power at AC-3, 400 V

7.5kW

Supporting protocol for Modbus

Supporting protocol for ASI

Depth

123.4mm

Number of command positions

0

Overload release current setting

10 .. 16A

Number of auxiliary contacts as normally open contact

1

Number of indicator lights

0

Supporting protocol for CAN

Rated operation current Ie

15.2A

With transformer

Suitable for emergency stop

Supporting protocol for DeviceNet

Width

45mm

Height

228mm

Supporting protocol for INTERBUS

Supporting protocol for LON

Power consumption

2.1W

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for other bus systems

With fuse

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SERCOS

Degree of protection (IP)

IP00

Rail mounting possible

External reset possible

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at DC

0 .. 0V

Release class

CLASS 10 A

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Rated operation power at AC-3, 230 V, 3-phase

4kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

AC

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Rated conditional short-circuit current, type 2, 400 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

Rated operation current at AC-3, 400 V

16A

Ambient temperature, upper operating limit

55°C

Rated power, 575 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.