Aleta.hr
Main Product Image

MSC-D-16-M17(230V50HZ)

Code: 1046652

ManufacturerRAZNO
Catalog number283150
Type
EAN code4015082831509

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 - 0V

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated control supply voltage Us at DC

0 - 0V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

16A

Rated operation current Ie

15.2A

Rated operation power at AC-3, 400 V

7.5kW

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

10 - 16A

Ambient temperature, upper operating limit

55°C

Power consumption

2.1W

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 400 V

50000A

Type of electrical connection of main circuit

Screw connection

Temperature compensated overload protection

Yes

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Release class

CLASS 10 A

Rail mounting possible

No

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

Number of command positions

0

External reset possible

No

Supporting protocol for TCP/IP

No

With fuse

No

Suitable for emergency stop

No

Degree of protection (IP)

IP00

Supporting protocol for CAN

No

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for PROFIBUS

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Width

45mm

Height

228mm

Depth

123.4mm

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for LON

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-16-M17(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

16A

Rated operation current Ie

15.2A

Rated operation power at AC-3, 400 V

7.5kW

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

10 .. 16A

Ambient temperature, upper operating limit

55°C

Power consumption

2.1W

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 400 V

50000A

Type of electrical connection of main circuit

Screw connection

Temperature compensated overload protection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Release class

CLASS 10 A

Rail mounting possible

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

Number of command positions

0

External reset possible

Supporting protocol for TCP/IP

With fuse

Suitable for emergency stop

Degree of protection (IP)

IP00

Supporting protocol for CAN

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

45mm

Height

228mm

Depth

123.4mm

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.