Technical specifications

Width45mm
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Number of command positions0
With transformerNo
Number of auxiliary contacts as normally closed contact0
Rated operation power at AC-3, 400 V11kW
Rated operation current Ie21.7A
Number of indicator lights0
Height228mm
Power consumption2.1W
Depth123.4mm
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for LONNo
Overload release current setting20 - 25A
Degree of protection (IP)IP00
External reset possibleNo
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at DC0 - 0V
Rail mounting possibleNo
Release classCLASS 10 A
Rated control supply voltage Us at AC 60HZ0 - 0V
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for EtherNet/IPNo
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Temperature compensated overload protectionYes
Degree of protection (NEMA)Other
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation current at AC-3, 400 V25A
Rated conditional short-circuit current, type 2, 400 V50000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-25-M25(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Number of command positions

0

With transformer

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 400 V

11kW

Rated operation current Ie

21.7A

Number of indicator lights

0

Height

228mm

Power consumption

2.1W

Depth

123.4mm

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for LON

Overload release current setting

20 .. 25A

Degree of protection (IP)

IP00

External reset possible

With short-circuit release

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Rated control supply voltage Us at DC

0 .. 0V

Rail mounting possible

Release class

CLASS 10 A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With fuse

Supporting protocol for SafetyBUS p

Voltage type for actuating

AC

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Type of motor starter

Direct online starter (DOL)

Supporting protocol for EtherNet/IP

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Temperature compensated overload protection

Degree of protection (NEMA)

Other

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

25A

Rated conditional short-circuit current, type 2, 400 V

50000A