Aleta.hr
Main Product Image

MSC-D-25-M25(230V50HZ)

Code: 1046653

ManufacturerRAZNO
Catalog number283151
Type
EAN code4015082831516

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 60HZ

0 - 0V

With short-circuit release

Yes

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

11kW

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

25A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 2, 400 V

50000A

Voltage type for actuating

AC

Rated operation current Ie

21.7A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

0 - 0V

Power consumption

2.1W

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rail mounting possible

No

Rated conditional short-circuit current, type 2, 230 V

50000A

Overload release current setting

20 - 25A

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of auxiliary contacts as normally open contact

1

Number of command positions

0

With transformer

No

Ambient temperature, upper operating limit

55°C

Rated power, 460 V, 60 Hz, 3-phase

0kW

Suitable for emergency stop

No

With fuse

No

Temperature compensated overload protection

Yes

Number of indicator lights

0

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP00

External reset possible

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Height

228mm

Width

45mm

Supporting protocol for DeviceNet Safety

No

Depth

123.4mm

Supporting protocol for TCP/IP

No

Supporting protocol for CAN

No

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for Modbus

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-25-M25(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

11kW

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

25A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 2, 400 V

50000A

Voltage type for actuating

AC

Rated operation current Ie

21.7A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

0 .. 0V

Power consumption

2.1W

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rail mounting possible

Rated conditional short-circuit current, type 2, 230 V

50000A

Overload release current setting

20 .. 25A

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of auxiliary contacts as normally open contact

1

Number of command positions

0

With transformer

Ambient temperature, upper operating limit

55°C

Rated power, 460 V, 60 Hz, 3-phase

0kW

Suitable for emergency stop

With fuse

Temperature compensated overload protection

Number of indicator lights

0

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP00

External reset possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

228mm

Width

45mm

Supporting protocol for DeviceNet Safety

Depth

123.4mm

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.