Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
With transformerNo
Height228mm
Rated operation power at AC-3, 400 V15kW
Number of auxiliary contacts as normally open contact1
Power consumption2.1W
Depth123.4mm
Number of command positions0
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Supporting protocol for CANNo
Supporting protocol for LONNo
Rated operation current Ie29.3A
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
Overload release current setting25 - 32A
Number of indicator lights0
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Rail mounting possibleNo
External reset possibleNo
Degree of protection (IP)IP00
Rated control supply voltage Us at DC0 - 0V
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ0 - 0V
With fuseNo
Supporting protocol for SERCOSNo
Release classCLASS 10 A
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Voltage type for actuatingAC
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for PROFINET CBANo
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V32A
Rated conditional short-circuit current, type 2, 230 V50000A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-32-M32(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

With transformer

Height

228mm

Rated operation power at AC-3, 400 V

15kW

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Depth

123.4mm

Number of command positions

0

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Supporting protocol for CAN

Supporting protocol for LON

Rated operation current Ie

29.3A

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Overload release current setting

25 .. 32A

Number of indicator lights

0

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Rail mounting possible

External reset possible

Degree of protection (IP)

IP00

Rated control supply voltage Us at DC

0 .. 0V

With short-circuit release

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With fuse

Supporting protocol for SERCOS

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for PROFINET CBA

Rated operation power at AC-3, 230 V, 3-phase

7.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

32A

Rated conditional short-circuit current, type 2, 230 V

50000A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.