Technical specifications

Depth95mm
Width45mm
Height180mm
With transformerNo
Power consumption2.6W
Number of auxiliary contacts as normally open contact1
Number of command positions0
Overload release current setting0.4 - 0.63A
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
External reset possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsNo
Rated operation current Ie0.6A
Number of indicator lights0
Rail mounting possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for CANNo
Supporting protocol for LONNo
Rated operation power at AC-3, 400 V0.18kW
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Degree of protection (IP)IP20
Supporting protocol for EtherNet/IPNo
With fuseNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Voltage type for actuatingDC
Release classCLASS 10 A
With short-circuit releaseYes
Rated operation power at AC-3, 230 V, 3-phase0.09kW
Rated operation current at AC-3, 400 V0.63A
Supporting protocol for PROFIsafeNo
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50000A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-0,63-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

95mm

Width

45mm

Height

180mm

With transformer

Power consumption

2.6W

Number of auxiliary contacts as normally open contact

1

Number of command positions

0

Overload release current setting

0.4 .. 0.63A

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

External reset possible

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for other bus systems

Rated operation current Ie

0.6A

Number of indicator lights

0

Rail mounting possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for CAN

Supporting protocol for LON

Rated operation power at AC-3, 400 V

0.18kW

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Degree of protection (IP)

IP20

Supporting protocol for EtherNet/IP

With fuse

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

DC

Release class

CLASS 10 A

With short-circuit release

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Rated operation current at AC-3, 400 V

0.63A

Supporting protocol for PROFIsafe

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50000A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.