Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Rated control supply voltage Us at AC 60HZ0 - 0V
With short-circuit releaseYes
Rated operation power at AC-3, 400 V0.25kW
Rated operation power at AC-3, 230 V, 3-phase0.12kW
Rated control supply voltage Us at DC24 - 24V
Rated operation current at AC-3, 400 V1A
Rated operation current Ie0.8A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Ambient temperature, upper operating limit55°C
Power consumption2.6W
Number of auxiliary contacts as normally closed contact0
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally open contact1
Release classCLASS 10 A
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Suitable for emergency stopNo
Coordination class according to IEC 60947-4-3Class 2
With transformerNo
Number of command positions0
Rail mounting possibleNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
With fuseNo
Degree of protection (IP)IP20
External reset possibleNo
Rated conditional short-circuit current, type 2, 400 V50000A
Rated power, 460 V, 60 Hz, 3-phase0kW
Number of indicator lights0
Degree of protection (NEMA)Other
Voltage type for actuatingDC
Overload release current setting0.63 - 1A
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Height180mm
Width45mm
Depth95mm
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-1-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Rated operation power at AC-3, 400 V

0.25kW

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated control supply voltage Us at DC

24 .. 24V

Rated operation current at AC-3, 400 V

1A

Rated operation current Ie

0.8A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Ambient temperature, upper operating limit

55°C

Power consumption

2.6W

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Number of auxiliary contacts as normally open contact

1

Release class

CLASS 10 A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 2

With transformer

Number of command positions

0

Rail mounting possible

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

With fuse

Degree of protection (IP)

IP20

External reset possible

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Number of indicator lights

0

Degree of protection (NEMA)

Other

Voltage type for actuating

DC

Overload release current setting

0.63 .. 1A

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

180mm

Width

45mm

Depth

95mm

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.