Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Suitable for emergency stopNo
Rated operation current Ie1.5A
Supporting protocol for ASINo
Number of auxiliary contacts as normally closed contact0
Depth95mm
Height180mm
Number of auxiliary contacts as normally open contact1
Supporting protocol for TCP/IPNo
Power consumption2.6W
Overload release current setting1 - 1.6A
Supporting protocol for LONNo
With transformerNo
Number of indicator lights0
Width45mm
Number of command positions0
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Rated operation power at AC-3, 400 V0.55kW
Degree of protection (IP)IP20
Rail mounting possibleNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for SERCOSNo
External reset possibleNo
Rated control supply voltage Us at DC24 - 24V
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
With short-circuit releaseYes
With fuseNo
Rated operation power at AC-3, 230 V, 3-phase0.25kW
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingDC
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Rated operation current at AC-3, 400 V1.6A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-1,6-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Suitable for emergency stop

Rated operation current Ie

1.5A

Supporting protocol for ASI

Number of auxiliary contacts as normally closed contact

0

Depth

95mm

Height

180mm

Number of auxiliary contacts as normally open contact

1

Supporting protocol for TCP/IP

Power consumption

2.6W

Overload release current setting

1 .. 1.6A

Supporting protocol for LON

With transformer

Number of indicator lights

0

Width

45mm

Number of command positions

0

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Rated operation power at AC-3, 400 V

0.55kW

Degree of protection (IP)

IP20

Rail mounting possible

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for SERCOS

External reset possible

Rated control supply voltage Us at DC

24 .. 24V

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

With short-circuit release

With fuse

Rated operation power at AC-3, 230 V, 3-phase

0.25kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Voltage type for actuating

DC

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Rated power, 460 V, 60 Hz, 3-phase

0kW

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

55°C

Rated operation current at AC-3, 400 V

1.6A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.