Details
- •Low-voltage switchgear and control gear (automation)
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Supporting protocol for TCP/IPNo
Number of indicator lights0
Supporting protocol for LONNo
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Power consumption2.6W
Supporting protocol for CANNo
Number of auxiliary contacts as normally open contact1
Supporting protocol for PROFIBUSNo
Depth95mm
Height180mm
Number of auxiliary contacts as normally closed contact0
Number of command positions0
Width45mm
With transformerNo
Supporting protocol for PROFIsafeNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
External reset possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFINET CBANo
With short-circuit releaseYes
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for other bus systemsNo
Release classCLASS 10
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
With fuseNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitScrew connection
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Rated operation current at AC-3, 400 V4A
Rated power, 575 V, 60 Hz, 3-phase0kW
Coordination class according to IEC 60947-4-3Class 2
Temperature compensated overload protectionYes
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.75kW
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 2, 400 V50000A
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 400 V1.5kW
Overload release current setting2.5 - 4A
Rail mounting possibleYes
Rated operation current Ie4A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user