Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth95mm
Width45mm
Number of indicator lights0
Number of command positions0
With transformerNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Power consumption2.6W
Rated operation power at AC-3, 400 V2.2kW
Height180mm
Rated operation current Ie5A
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for CANNo
Overload release current setting4 - 6.3A
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
External reset possibleNo
Release classCLASS 10
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
With short-circuit releaseYes
Supporting protocol for EtherNet/IPNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for INTERBUS-SafetyNo
With fuseNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Rated operation current at AC-3, 400 V6.3A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 2, 400 V50000A
Degree of protection (NEMA)Other
Rated power, 460 V, 60 Hz, 3-phase0kW
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-6,3-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

95mm

Width

45mm

Number of indicator lights

0

Number of command positions

0

With transformer

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Power consumption

2.6W

Rated operation power at AC-3, 400 V

2.2kW

Height

180mm

Rated operation current Ie

5A

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for CAN

Overload release current setting

4 .. 6.3A

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Rail mounting possible

External reset possible

Release class

CLASS 10

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Supporting protocol for EtherNet/IP

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Type of electrical connection of main circuit

Screw connection

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS-Safety

With fuse

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated operation current at AC-3, 400 V

6.3A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Degree of protection (NEMA)

Other

Rated power, 460 V, 60 Hz, 3-phase

0kW

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.