Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at DC
24 - 24V
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Voltage type for actuating
DC
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
6.3A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation power at AC-3, 400 V
2.2kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
5A
Number of auxiliary contacts as normally open contact
1
Power consumption
2.6W
Overload release current setting
4 - 6.3A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Yes
Release class
CLASS 10
Rated conditional short-circuit current, type 2, 400 V
50000A
Rail mounting possible
No
Number of command positions
0
Suitable for emergency stop
No
Ambient temperature, upper operating limit
55°C
With transformer
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
180mm
Depth
95mm
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
External reset possible
No
With fuse
No
Number of indicator lights
0
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
No
Supporting protocol for Modbus
No
Supporting protocol for CAN
No
Supporting protocol for DeviceNet
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
From same serie
MSC-D-6,3-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Voltage type for actuating
DC
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
6.3A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation power at AC-3, 400 V
2.2kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
5A
Number of auxiliary contacts as normally open contact
1
Power consumption
2.6W
Overload release current setting
4 .. 6.3A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Release class
CLASS 10
Rated conditional short-circuit current, type 2, 400 V
50000A
Rail mounting possible
Number of command positions
0
Suitable for emergency stop
Ambient temperature, upper operating limit
55°C
With transformer
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
180mm
Depth
95mm
Supporting protocol for INTERBUS
Supporting protocol for PROFINET IO
Supporting protocol for ASI
External reset possible
With fuse
Number of indicator lights
0
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
From same serie
We use cookies to enhance your experience.