Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height228mm
Depth123.4mm
Power consumption0.9W
Number of auxiliary contacts as normally open contact1
Rated operation power at AC-3, 400 V7.5kW
Width45mm
Number of auxiliary contacts as normally closed contact0
Overload release current setting10 - 16A
Supporting protocol for ASINo
Number of command positions0
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
With transformerNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Number of indicator lights0
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Rated operation current Ie15.2A
Type of electrical connection of main circuitScrew connection
Supporting protocol for SUCONETNo
Degree of protection (IP)IP00
With short-circuit releaseYes
Supporting protocol for SERCOSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Rail mounting possibleNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Rated control supply voltage Us at DC24 - 24V
Release classCLASS 10 A
With fuseNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for ModbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNet SafetyNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Temperature compensated overload protectionYes
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase4kW
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation current at AC-3, 400 V16A
Coordination class according to IEC 60947-4-3Class 2
Type of motor starterDirect online starter (DOL)
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M17(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

228mm

Depth

123.4mm

Power consumption

0.9W

Number of auxiliary contacts as normally open contact

1

Rated operation power at AC-3, 400 V

7.5kW

Width

45mm

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

10 .. 16A

Supporting protocol for ASI

Number of command positions

0

Supporting protocol for PROFIBUS

Suitable for emergency stop

With transformer

Supporting protocol for INTERBUS

Supporting protocol for CAN

Number of indicator lights

0

Supporting protocol for LON

Supporting protocol for TCP/IP

Rated operation current Ie

15.2A

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SUCONET

Degree of protection (IP)

IP00

With short-circuit release

Supporting protocol for SERCOS

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Rail mounting possible

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Rated control supply voltage Us at DC

24 .. 24V

Release class

CLASS 10 A

With fuse

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for Modbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Data-Highway

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet Safety

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Temperature compensated overload protection

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

4kW

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation current at AC-3, 400 V

16A

Coordination class according to IEC 60947-4-3

Class 2

Type of motor starter

Direct online starter (DOL)

Supporting protocol for SafetyBUS p