Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height228mm
Depth123.4mm
Power consumption0.9W
Width45mm
With transformerNo
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V15kW
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Number of indicator lights0
Number of command positions0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Rated operation current Ie29.3A
External reset possibleNo
Supporting protocol for INTERBUSNo
Number of auxiliary contacts as normally closed contact0
Overload release current setting25 - 32A
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Number of auxiliary contacts as normally open contact1
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Degree of protection (IP)IP00
Supporting protocol for ASINo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFINET IONo
Ambient temperature, upper operating limit55°C
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for Foundation FieldbusNo
Temperature compensated overload protectionYes
Supporting protocol for SafetyBUS pNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFIsafeNo
With short-circuit releaseYes
Rated operation current at AC-3, 400 V32A
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rated conditional short-circuit current, type 2, 230 V50000A
Supporting protocol for PROFINET CBANo
Release classCLASS 10 A
With fuseNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 400 V50000A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingDC
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-32-M32(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

228mm

Depth

123.4mm

Power consumption

0.9W

Width

45mm

With transformer

Suitable for emergency stop

Rated operation power at AC-3, 400 V

15kW

Supporting protocol for Modbus

Supporting protocol for SUCONET

Number of indicator lights

0

Number of command positions

0

Supporting protocol for TCP/IP

Supporting protocol for LON

Supporting protocol for PROFIBUS

Rated operation current Ie

29.3A

External reset possible

Supporting protocol for INTERBUS

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

25 .. 32A

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Number of auxiliary contacts as normally open contact

1

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Degree of protection (IP)

IP00

Supporting protocol for ASI

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFINET IO

Ambient temperature, upper operating limit

55°C

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for Foundation Fieldbus

Temperature compensated overload protection

Supporting protocol for SafetyBUS p

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFIsafe

With short-circuit release

Rated operation current at AC-3, 400 V

32A

Rated operation power at AC-3, 230 V, 3-phase

7.5kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Supporting protocol for PROFINET CBA

Release class

CLASS 10 A

With fuse

Type of motor starter

Direct online starter (DOL)

Supporting protocol for EtherNet/IP

Rated conditional short-circuit current, type 2, 400 V

50000A

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Voltage type for actuating

DC

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.