Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-1-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
90mm
Power consumption
1.4W
With transformer
Height
95mm
Rated operation power at AC-3, 400 V
0.25kW
Depth
185mm
Suitable for emergency stop
Number of command positions
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated operation current Ie
0.8A
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for Modbus
Number of indicator lights
0
Overload release current setting
0.63 .. 1A
Supporting protocol for other bus systems
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for SERCOS
With short-circuit release
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS-Safety
External reset possible
Rail mounting possible
With fuse
Release class
CLASS 10 A
Supporting protocol for CAN
Supporting protocol for DeviceNet
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Type of motor starter
Reversing starter
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Voltage type for actuating
AC
Ambient temperature, upper operating limit
55°C
Supporting protocol for DeviceNet Safety
Rated operation current at AC-3, 400 V
1A
Supporting protocol for Foundation Fieldbus
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for PROFIsafe
Degree of protection (NEMA)
Other
Supporting protocol for SafetyBUS p
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for AS-Interface Safety at Work
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for PROFINET CBA