Technical specifications

Width90mm
Number of auxiliary contacts as normally open contact0
With transformerNo
Number of command positions0
Number of indicator lights0
Overload release current setting1.6 - 2.5A
Rated operation current Ie1.9A
Height95mm
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Depth185mm
Rated operation power at AC-3, 400 V0.75kW
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Power consumption1.4W
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Foundation FieldbusNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
External reset possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for PROFINET IONo
Type of motor starterReversing starter
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingAC
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
Supporting protocol for EtherNet/IPNo
With fuseNo
Supporting protocol for PROFIsafeNo
Rail mounting possibleNo
Supporting protocol for SafetyBUS pNo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for other bus systemsNo
Supporting protocol for PROFINET CBANo
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V50000A
Rated operation current at AC-3, 400 V2.5A
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-2,5-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

90mm

Number of auxiliary contacts as normally open contact

0

With transformer

Number of command positions

0

Number of indicator lights

0

Overload release current setting

1.6 .. 2.5A

Rated operation current Ie

1.9A

Height

95mm

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Depth

185mm

Rated operation power at AC-3, 400 V

0.75kW

Supporting protocol for LON

Supporting protocol for TCP/IP

Power consumption

1.4W

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for Foundation Fieldbus

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

External reset possible

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for PROFINET IO

Type of motor starter

Reversing starter

Supporting protocol for DeviceNet Safety

Voltage type for actuating

AC

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

Supporting protocol for EtherNet/IP

With fuse

Supporting protocol for PROFIsafe

Rail mounting possible

Supporting protocol for SafetyBUS p

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for other bus systems

Supporting protocol for PROFINET CBA

With short-circuit release

Supporting protocol for INTERBUS-Safety

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

2.5A

Ambient temperature, upper operating limit

55°C

Rated power, 575 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection