Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth185mm
Width90mm
Height95mm
With transformerNo
Number of auxiliary contacts as normally open contact0
Number of command positions0
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Number of indicator lights0
Supporting protocol for ModbusNo
Power consumption1.4W
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Rated operation current Ie6.6A
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Rated operation power at AC-3, 400 V3kW
Overload release current setting6.3 - 10A
Suitable for emergency stopNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ230 - 230V
External reset possibleNo
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Rated control supply voltage Us at DC0 - 0V
With short-circuit releaseYes
Supporting protocol for PROFINET IONo
Release classCLASS 10 A
With fuseNo
Supporting protocol for PROFINET CBANo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Foundation FieldbusNo
Type of motor starterReversing starter
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Supporting protocol for PROFIsafeNo
Rated operation current at AC-3, 400 V7A
Rated power, 575 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 2, 400 V150A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-10-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

185mm

Width

90mm

Height

95mm

With transformer

Number of auxiliary contacts as normally open contact

0

Number of command positions

0

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for Data-Highway

Supporting protocol for CAN

Number of indicator lights

0

Supporting protocol for Modbus

Power consumption

1.4W

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Rated operation current Ie

6.6A

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for INTERBUS

Rated operation power at AC-3, 400 V

3kW

Overload release current setting

6.3 .. 10A

Suitable for emergency stop

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

External reset possible

Supporting protocol for TCP/IP

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Rated control supply voltage Us at DC

0 .. 0V

With short-circuit release

Supporting protocol for PROFINET IO

Release class

CLASS 10 A

With fuse

Supporting protocol for PROFINET CBA

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for Foundation Fieldbus

Type of motor starter

Reversing starter

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Voltage type for actuating

AC

Supporting protocol for PROFIsafe

Rated operation current at AC-3, 400 V

7A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 2, 400 V

150A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.