Technical specifications
MSC-R-10-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Depth
185mm
Width
90mm
Height
95mm
With transformer
Number of auxiliary contacts as normally open contact
0
Number of command positions
0
Supporting protocol for LON
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for Data-Highway
Supporting protocol for CAN
Number of indicator lights
0
Supporting protocol for Modbus
Power consumption
1.4W
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Rated operation current Ie
6.6A
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for INTERBUS
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
6.3 .. 10A
Suitable for emergency stop
Rail mounting possible
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
External reset possible
Supporting protocol for TCP/IP
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Rated control supply voltage Us at DC
0 .. 0V
With short-circuit release
Supporting protocol for PROFINET IO
Release class
CLASS 10 A
With fuse
Supporting protocol for PROFINET CBA
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Type of motor starter
Reversing starter
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Voltage type for actuating
AC
Supporting protocol for PROFIsafe
Rated operation current at AC-3, 400 V
7A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Coordination class according to IEC 60947-4-3
Class 1
Rated conditional short-circuit current, type 2, 400 V
150A
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A