Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width90mm
With transformerNo
Rated operation current Ie8.5A
Power consumption1.4W
Height95mm
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact0
Rated operation power at AC-3, 400 V4kW
Depth185mm
Number of command positions0
Number of auxiliary contacts as normally closed contact0
Number of indicator lights0
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Overload release current setting6.3 - 10A
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
External reset possibleNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Rated control supply voltage Us at DC0 - 0V
Rated control supply voltage Us at AC 50HZ230 - 230V
Release classCLASS 10 A
With short-circuit releaseYes
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With fuseNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Supporting protocol for SafetyBUS pNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V9A
Type of motor starterReversing starter
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 2, 400 V150A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Voltage type for actuatingAC
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-10-M9(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

90mm

With transformer

Rated operation current Ie

8.5A

Power consumption

1.4W

Height

95mm

Suitable for emergency stop

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-3, 400 V

4kW

Depth

185mm

Number of command positions

0

Number of auxiliary contacts as normally closed contact

0

Number of indicator lights

0

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for ASI

Overload release current setting

6.3 .. 10A

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

External reset possible

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for Data-Highway

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Release class

CLASS 10 A

With short-circuit release

Type of electrical connection of main circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With fuse

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Supporting protocol for SafetyBUS p

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

9A

Type of motor starter

Reversing starter

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 2, 400 V

150A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Voltage type for actuating

AC

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.