Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-16-M17(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
90mm
Height
123.4mm
Depth
228mm
Power consumption
2.1W
With transformer
Rated operation power at AC-3, 400 V
7.5kW
Number of command positions
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of indicator lights
0
Suitable for emergency stop
Rated operation current Ie
15.2A
Overload release current setting
10 .. 16A
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Rail mounting possible
Rated control supply voltage Us at AC 60HZ
0 .. 0V
External reset possible
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at DC
0 .. 0V
Degree of protection (IP)
IP00
Supporting protocol for SERCOS
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Release class
CLASS 10 A
Supporting protocol for AS-Interface Safety at Work
With short-circuit release
Type of electrical connection of main circuit
Screw connection
Supporting protocol for other bus systems
With fuse
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Rated operation power at AC-3, 230 V, 3-phase
4kW
Supporting protocol for PROFINET IO
Type of motor starter
Reversing starter
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Voltage type for actuating
AC
Supporting protocol for PROFIsafe
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Rated operation current at AC-3, 400 V
16A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other