Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Type of motor starter
Reversing starter
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 50HZ
230 - 230V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated operation power at AC-3, 400 V
15kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
25 - 32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
32A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current Ie
29.3A
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Release class
CLASS 10 A
Number of command positions
0
With transformer
No
Suitable for emergency stop
No
Degree of protection (IP)
IP00
Supporting protocol for TCP/IP
No
With fuse
No
Number of auxiliary contacts as normally open contact
0
Supporting protocol for PROFIBUS
No
Rail mounting possible
Yes
Degree of protection (NEMA)
Other
Supporting protocol for CAN
No
Supporting protocol for PROFINET CBA
No
External reset possible
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for INTERBUS
No
Supporting protocol for Foundation Fieldbus
No
Number of indicator lights
0
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Supporting protocol for SUCONET
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Width
90mm
Height
123.4mm
Depth
228mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
No
MSC-R-32-M32(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Reversing starter
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated operation power at AC-3, 400 V
15kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
25 .. 32A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
32A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current Ie
29.3A
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Release class
CLASS 10 A
Number of command positions
0
With transformer
Suitable for emergency stop
Degree of protection (IP)
IP00
Supporting protocol for TCP/IP
With fuse
Number of auxiliary contacts as normally open contact
0
Supporting protocol for PROFIBUS
Rail mounting possible
Degree of protection (NEMA)
Other
Supporting protocol for CAN
Supporting protocol for PROFINET CBA
External reset possible
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for Foundation Fieldbus
Number of indicator lights
0
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for SUCONET
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Width
90mm
Height
123.4mm
Depth
228mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
We use cookies to enhance your experience.