Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Type of motor starter
Reversing starter
Rated operation power at AC-3, 400 V
0.18kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
With short-circuit release
Yes
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current Ie
0.6A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
0.63A
Overload release current setting
0.4 - 0.63A
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
90mm
Height
95mm
Depth
185mm
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Power consumption
2.6W
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Number of command positions
0
With transformer
No
Rail mounting possible
No
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
External reset possible
No
With fuse
No
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
No
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
From same serie
MSC-R-0,63-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of motor starter
Reversing starter
Rated operation power at AC-3, 400 V
0.18kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With short-circuit release
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current Ie
0.6A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
0.63A
Overload release current setting
0.4 .. 0.63A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
90mm
Height
95mm
Depth
185mm
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Power consumption
2.6W
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Number of command positions
0
With transformer
Rail mounting possible
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
External reset possible
With fuse
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
From same serie
We use cookies to enhance your experience.