  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Rated operation power at AC-3, 400 V0.55kW
Power consumption2.6W
Height95mm
Depth185mm
Width90mm
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated operation current Ie1.5A
Supporting protocol for PROFIBUSNo
Number of indicator lights0
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Overload release current setting1 - 1.6A
Supporting protocol for CANNo
Number of command positions0
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Suitable for emergency stopNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Rail mounting possibleNo
With short-circuit releaseYes
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Release classCLASS 10 A
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFINET IONo
Type of electrical connection of main circuitScrew connection
Rated operation power at AC-3, 230 V, 3-phase0.25kW
Supporting protocol for PROFIsafeNo
Type of motor starterReversing starter
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Supporting protocol for PROFINET CBANo
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation current at AC-3, 400 V1.6A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-1,6-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Rated operation power at AC-3, 400 V

0.55kW

Power consumption

2.6W

Height

95mm

Depth

185mm

Width

90mm

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated operation current Ie

1.5A

Supporting protocol for PROFIBUS

Number of indicator lights

0

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for ASI

Overload release current setting

1 .. 1.6A

Supporting protocol for CAN

Number of command positions

0

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Suitable for emergency stop

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Rail mounting possible

With short-circuit release

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

With fuse

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Release class

CLASS 10 A

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFINET IO

Type of electrical connection of main circuit

Screw connection

Rated operation power at AC-3, 230 V, 3-phase

0.25kW

Supporting protocol for PROFIsafe

Type of motor starter

Reversing starter

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Voltage type for actuating

DC

Supporting protocol for PROFINET CBA

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation current at AC-3, 400 V

1.6A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.