Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterReversing starter
With short-circuit releaseYes
Rated operation power at AC-3, 400 V0.55kW
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Rated operation current at AC-3, 400 V1.6A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation power at AC-3, 230 V, 3-phase0.25kW
Number of auxiliary contacts as normally open contact0
Rated operation current Ie1.5A
Number of auxiliary contacts as normally closed contact0
Rated control supply voltage Us at AC 60HZ0 - 0V
Temperature compensated overload protectionYes
Release classCLASS 10 A
Number of command positions0
Rated conditional short-circuit current, type 2, 230 V50000A
Type of electrical connection for auxiliary- and control current circuitScrew connection
Coordination class according to IEC 60947-4-3Class 2
Suitable for emergency stopNo
Power consumption2.6W
Overload release current setting1 - 1.6A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of electrical connection of main circuitScrew connection
With transformerNo
Ambient temperature, upper operating limit55°C
Rail mounting possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width90mm
Height95mm
Depth185mm
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
External reset possibleNo
Number of indicator lights0
Degree of protection (IP)IP20
With fuseNo
Supporting protocol for PROFIBUSNo
Degree of protection (NEMA)Other
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-1,6-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

With short-circuit release

Rated operation power at AC-3, 400 V

0.55kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation current at AC-3, 400 V

1.6A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation power at AC-3, 230 V, 3-phase

0.25kW

Number of auxiliary contacts as normally open contact

0

Rated operation current Ie

1.5A

Number of auxiliary contacts as normally closed contact

0

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Temperature compensated overload protection

Release class

CLASS 10 A

Number of command positions

0

Rated conditional short-circuit current, type 2, 230 V

50000A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Suitable for emergency stop

Power consumption

2.6W

Overload release current setting

1 .. 1.6A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of electrical connection of main circuit

Screw connection

With transformer

Ambient temperature, upper operating limit

55°C

Rail mounting possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

90mm

Height

95mm

Depth

185mm

Supporting protocol for DeviceNet

Supporting protocol for ASI

External reset possible

Number of indicator lights

0

Degree of protection (IP)

IP20

With fuse

Supporting protocol for PROFIBUS

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.