Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height95mm
Depth185mm
Width90mm
With transformerNo
Power consumption2.6W
Number of command positions0
Rated operation power at AC-3, 400 V0.75kW
Number of auxiliary contacts as normally open contact0
Overload release current setting1.6 - 2.5A
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Suitable for emergency stopNo
Supporting protocol for CANNo
Number of indicator lights0
Supporting protocol for INTERBUSNo
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie1.9A
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for SUCONETNo
External reset possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rail mounting possibleNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
With short-circuit releaseYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
With fuseNo
Supporting protocol for PROFINET IONo
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for INTERBUS-SafetyNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of motor starterReversing starter
Type of electrical connection for auxiliary- and control current circuitScrew connection
Voltage type for actuatingDC
Degree of protection (IP)IP20
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10 A
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V2.5A
Rated conditional short-circuit current, type 2, 400 V50000A
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-2,5-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

95mm

Depth

185mm

Width

90mm

With transformer

Power consumption

2.6W

Number of command positions

0

Rated operation power at AC-3, 400 V

0.75kW

Number of auxiliary contacts as normally open contact

0

Overload release current setting

1.6 .. 2.5A

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Suitable for emergency stop

Supporting protocol for CAN

Number of indicator lights

0

Supporting protocol for INTERBUS

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

1.9A

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for Data-Highway

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for SUCONET

External reset possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rail mounting possible

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SERCOS

With short-circuit release

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

With fuse

Supporting protocol for PROFINET IO

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Supporting protocol for INTERBUS-Safety

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of motor starter

Reversing starter

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

DC

Degree of protection (IP)

IP20

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10 A

Supporting protocol for Foundation Fieldbus

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

2.5A

Rated conditional short-circuit current, type 2, 400 V

50000A

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.