ManufacturerRAZNO
Catalog number283204
Type
EAN code4015082832049

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Voltage type for actuating

DC

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated operation power at AC-3, 400 V

7.5kW

Type of motor starter

Reversing starter

With short-circuit release

Yes

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

24 - 24V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Overload release current setting

10 - 16A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

16A

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Yes

Power consumption

0.9W

Type of electrical connection of main circuit

Screw connection

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Number of auxiliary contacts as normally open contact

0

Number of indicator lights

0

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Rail mounting possible

No

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for TCP/IP

No

Degree of protection (NEMA)

Other

External reset possible

No

Suitable for emergency stop

No

With fuse

No

Degree of protection (IP)

IP00

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for DeviceNet

No

Supporting protocol for Modbus

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Data-Highway

No

Supporting protocol for CAN

No

Supporting protocol for SERCOS

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for ASI

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Height

123.4mm

Supporting protocol for SafetyBUS p

No

Width

90mm

Depth

228mm


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-R-16-M17(24VDC)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Voltage type for actuating

DC

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated operation power at AC-3, 400 V

7.5kW

Type of motor starter

Reversing starter

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

24 .. 24V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Overload release current setting

10 .. 16A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

16A

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Power consumption

0.9W

Type of electrical connection of main circuit

Screw connection

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Number of auxiliary contacts as normally open contact

0

Number of indicator lights

0

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Rail mounting possible

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

External reset possible

Suitable for emergency stop

With fuse

Degree of protection (IP)

IP00

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for ASI

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Height

123.4mm

Supporting protocol for SafetyBUS p

Width

90mm

Depth

228mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.