Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width90mm
Depth228mm
Height123.4mm
Number of command positions0
Rated operation power at AC-3, 400 V15kW
With transformerNo
Power consumption0.9W
Number of auxiliary contacts as normally open contact0
Overload release current setting25 - 32A
Rated operation current Ie29.3A
Number of auxiliary contacts as normally closed contact0
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Suitable for emergency stopNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFIBUSNo
External reset possibleNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP00
Rated control supply voltage Us at AC 60HZ0 - 0V
Rail mounting possibleNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for SERCOSNo
Release classCLASS 10 A
Supporting protocol for EtherNet/IPNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
With short-circuit releaseYes
With fuseNo
Supporting protocol for PROFINET IONo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Type of motor starterReversing starter
Voltage type for actuatingDC
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rated operation current at AC-3, 400 V32A
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-32-M32(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

90mm

Depth

228mm

Height

123.4mm

Number of command positions

0

Rated operation power at AC-3, 400 V

15kW

With transformer

Power consumption

0.9W

Number of auxiliary contacts as normally open contact

0

Overload release current setting

25 .. 32A

Rated operation current Ie

29.3A

Number of auxiliary contacts as normally closed contact

0

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for LON

Suitable for emergency stop

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for PROFIBUS

External reset possible

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP00

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rail mounting possible

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for SERCOS

Release class

CLASS 10 A

Supporting protocol for EtherNet/IP

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

With short-circuit release

With fuse

Supporting protocol for PROFINET IO

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Type of motor starter

Reversing starter

Voltage type for actuating

DC

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

7.5kW

Rated operation current at AC-3, 400 V

32A

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.