Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Release characteristicB
Built-in depth70.5mm
Rated insulation voltage Ui440V
Rated voltage230V
Rated current32A
Frequency50 - 60Hz
Pollution degree2
Over voltage category3
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)1
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Degree of protection (IP)IP20
Width in number of modular spacings1
Power loss3.5W
Concurrently switching neutral conductorNo
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B32/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Release characteristic

B

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Rated voltage

230V

Rated current

32A

Frequency

50 .. 60Hz

Pollution degree

2

Over voltage category

3

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

1

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Power loss

3.5W

Concurrently switching neutral conductor

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible