Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Voltage typeAC
Rated current25A
Built-in depth70.5mm
Rated voltage230V
Release characteristicC
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Over voltage category3
Degree of protection (IP)IP20
Explosion-proofNo
Number of protected poles1
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Width in number of modular spacings1
Pollution degree2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss2.8W
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C25/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC

Rated current

25A

Built-in depth

70.5mm

Rated voltage

230V

Release characteristic

C

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP20

Explosion-proof

Number of protected poles

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Width in number of modular spacings

1

Pollution degree

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

2.8W

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.