Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Current limiting class3
Explosion-proofNo
Width in number of modular spacings1
Frequency50 - 60Hz
Release characteristicZ
Number of protected poles1
Power loss2.8W
Built-in depth70.5mm
Rated insulation voltage Ui440V
Rated current6A
Rated voltage230V
Pollution degree2
Over voltage category3
Voltage typeAC
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes

Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-Z6/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Current limiting class

3

Explosion-proof

Width in number of modular spacings

1

Frequency

50 .. 60Hz

Release characteristic

Z

Number of protected poles

1

Power loss

2.8W

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Rated current

6A

Rated voltage

230V

Pollution degree

2

Over voltage category

3

Voltage type

AC

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

From same serie

Related products