Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current10A
Number of poles (total)2
Release characteristicC
Rated voltage230V
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Built-in depth70.5mm
Rated insulation voltage Ui440V
Voltage typeAC
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Power loss1.6W
Concurrently switching neutral conductorYes
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings2
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Explosion-proofNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C10/1N

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

10A

Number of poles (total)

2

Release characteristic

C

Rated voltage

230V

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Voltage type

AC

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Power loss

1.6W

Concurrently switching neutral conductor

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

2

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.