  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated current16A
Voltage typeAC
Rated voltage230V
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Frequency50 - 60Hz
Pollution degree2
Release characteristicC
Degree of protection (IP)IP20
Explosion-proofNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles1
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings2
Power loss2.7W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C16/1N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated current

16A

Voltage type

AC

Rated voltage

230V

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Frequency

50 .. 60Hz

Pollution degree

2

Release characteristic

C

Degree of protection (IP)

IP20

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

1

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Power loss

2.7W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA